N-Light™ MaxiSampler: Revolutionizing Surface Sampling

MaxiSampler img
Background image

N-Light™ MaxiSampler: Advanced Surface Sampling Device

Large surface areas often pose a challenge for accurate and efficient environmental testing, but not anymore. Introducing the N-Light™ MaxiSampler, the innovative surface sampling solution from NEMIS Technologies. Designed for compatibility with rapid, on-site testing platforms, the N-Light™ MaxiSampler ensures reliable sample collection with minimal effort.

Sampling: A crucial part of environmental monitoring in food factories

Sampling in production rooms according to sampling plan

Sample transfer (time frame and temperature important!)

Sample analysis: On-site rapid test or at external laboratory

Data analysis decision on corrective actions planning of follow-up sampling

Why is the choice of the sampling device important?

The sampling device plays a pivotal role in the effectiveness of environmental monitoring. A carefully selected device ensures accurate and reliable sample collection by addressing key factors critical to the sampling process:

Force Application for Cell Removal:

Force Application for Cell Removal:

The device must enable the application of sufficient force to dislodge even strongly attached microorganisms from surfaces, ensuring comprehensive sample collection.

Surface Area Coverage:

Surface Area Coverage:

An optimized sampling device ensures that large or irregular surface areas are covered efficiently, minimizing missed zones and enhancing sampling accuracy.

Effectiveness and Capacity for Cell Pick-Up:

Effectiveness and Capacity for Cell Pick-Up:

The design and material of the device, such as a flocked fiber coating, should maximize the adhesion of microorganisms, ensuring a higher yield of collected cells.

Minimized Cross-Contamination Risk:

Minimized Cross-Contamination Risk:

A well-designed device reduces the risk of introducing contaminants during sampling, preserving the integrity of the collected sample.

Microorganism Viability During Transport:

Microorganism Viability During Transport:

The device must maintain the survival and/or growth of collected microorganisms during transportation to the testing site, ensuring the reliability of subsequent analyses.

Effective Cell Release into Testing Media

A high-quality sampling device facilitates the efficient transfer of collected microorganisms into a resuspension buffer or enrichment medium, ensuring that the sample is fully utilized in the testing process.

Talk to expert about your current sampling method
Contact us

N-Light™ MaxiSampler: a new approach to sampling of large surfaces

The N-Light™ MaxiSampler is the first large-surface sampling device designed specifically for compatibility with rapid, on-site tube tests. This patent-pending innovation combines robust functionality with intuitive design, enabling effective sampling of extensive areas with ease.

 <span>N-Light™ MaxiSampler:</span> a new approach to sampling of large surfaces

Ideal for applications in food safety, healthcare, and industrial hygiene, the N-Light™ MaxiSampler offers a straightforward, cost-effective solution for sampling large surfaces. Its user-friendly design makes it accessible to professionals with varying levels of training, ensuring accurate and reliable results.

N-Light™ MaxiSampler vs N-Light™ swab

Designed for Large Surface Coverage
Designed for Large Surface Coverage
Ideal for Hard-to-Reach Areas
Ideal for Hard-to-Reach Areas

N-Light™ MaxiSampler compatible with the following N-Light™ pathogen tests:

N-Light™ MaxiSampler is suitable for sampling food processing areas and equipment as part of an environmental monitoring program.

The N-Light™ MaxiSampler has been validated for sampling visually clean surfaces in combination with the following N-Light™ tests and moistening solutions.

 

 

N-Light™ Tests
N-Light™ MaxiSampler
PBS buffer

REF
00060
BPW buffer

REF
00062
Neutralizer

REF
00064
REF
00009

REF 00009

REF
00048

REF 00048

REF
00014

REF 00014

REF
00029

REF 00029

Simple, Effective, Testing process

PREPARATION Repeat for 5-6 samples per reservoir and buffer tube
SAMPLING

Add the N-Light™ buffer to the sterile reservoir.

Mark/label the pouch according to your test plan. Open the sealed pouch.

Remove the N-Light™ Maxi-Sampler from the pouch and wet it in the buffer.

Store the wetted MaxiSampler again in its pouch and use it within 4 hours.

Sample surface areas of up to 0.3 m² by scraping the area in 3 directions with some force.

Place the N-Light™ Maxi-Sampler back into the pouch after sampling and proceed with step 3 within 4 hours.

TIPS:
  1. For sampling wet surfaces, using dry MaxiSamplers is acceptable.
  2. Use the tip of the MaxiSampler swab to sample grooves and holes in the sampling area.
  3. Change the inclination of the handle during swabbing.
Check full instruction

See how our N Light™ MaxiSampler works:

Check our product webinar to see the performance of N-Light™ MaxiSampler

Check webinar

Training

At NEMIS, your success is our priority. Our experts are here to guide you with comprehensive training resources, including instructional videos, to help your team confidently and accurately perform procedures. For on-demand training requests, please contact us at techsupport@nemistech.com.

Watch our virtual training video

FAQs

The N-Light™ MaxiSampler is compatible with N-Light™ L. monocytogenes, N-Light™ Listeria spp., N-Light™ Salmonella Risk, and N-Light™ E. coli tests.
Swabbing with the MaxiSampler is as easy as with a normal swab. Wipe across the sampled area two to three times in different directions while inclining the handle to both side. Apply ample pressure to the surface with the robust handle, this helps to remove bacteria firmly attached to the surface.
If you sample dry surfaces, moistening the MaxiSampler with N-Light™ Neutralizer or N-Light™ BPW is essential. Wet surfaces can be sampled with the dry MaxiSampler.
Maximum 4 hours at room temperature.
The N-Light™ MaxiSampler can be used to sample surface areas up to 0.3 m² (e.g. 30×30 cm or 50 x 50 cm, making it ideal for sampling large surfaces for environmental monitoring.
It is best used for large, flat surfaces such as conyeyor belts, tables,carts, doors, plastic curtains, floors, machine covers and casings, walls, and countertops. It can be applied on all types of surface materials (stainless steel, plastic, ceramics).
Best is to place the MaxiSampler back in its pouch after sampling. Avoid touching the swab part with your hands or other sources of contamination. Then transfer the sample as soon as possible to the N-Light™ test tube.
Open cap of the test tube, then insert the swab part of the MaxiSampler in the tube with the tip pointing down, then turn the handle upwards to unlock the click mechanism, then let the swab part slip down into the test tube and screw the cap back on the tube.
Rising of the MaxiSampler surface with the enrichment broth in the N-Light™ test tubes is very important. By this, bacteria are washed to the bottom of the tube where growth in the right medium and at the right temperature takes place. For rinsing, move the closed N-Light™ tube in horizontal position, with the coated part of the MaxiSampler facing down. Then incline the tube upwards and downwards at least ten times, which will cause the liquid in the tube to flow back and forth over the fiber coating.
In case of N-Light™ Listeria spp. and N-Light™ Salmonella Risk tests, remove the MaxiSampler swab from the tube after rinsing. This is done by sticking the upper end of the disassembled handle into the upper end of the MaxiSampler swab inside the tube and then drawing the swab out. While doing this, leave as much enrichment broth as possible in the tube by sloughing off liquid from the swab at the tube wall. Discard handle and swab in a waste bin. Follow instructions for use of N-Light™ Listeria spp. and N-Light™ Salmonella Risk tests for further steps. In case of N-Light™ Listeria monocytogenes and N-Light™ Escherichia coli, the swab part of the MaxiSampler is left in the test tube. Before starting incubation, don’t forget to press the cap of the N-Light™ test tubes down for locking the biosafety mechanism.
There is no need to reuse the MaxiSampler as each MaxiSampler comes with a swab attached to a handle.

Support

Software Support
Whether you’re setting up our software or need troubleshooting help, check our FAQ, online resources, or contact techsupport@nemistech.com.
Document Search
From user manuals to product inserts, access essential product information to keep your operations running smoothly.
Customer Support
Have questions or special requests? Explore our FAQ, other technical resources, or reach out to us at techsupport@nemistech.com. We’re here to help!

Talk to an Expert About Your Sampling method

Book a demo